Sensing Mode (General)
Proximity
Sensing Mode (Detailed)
Time of Flight
Housing Style
Barrel
Primary Housing Material
PBT
Input/Output
Analog & Discrete
Indicator
LED(s)
Analog Output Configuration
4-20 mA
Analog Resolution/Discrete Repeatability
+/- 0.25% of measured distance (1.0 min)
Max Sensing Distance (mm)
2000
Minimum Sensing Distance (mm)
300
Sensing Beam
Ultrasonic
Power Supply
12-24 V dc
Adjustments
Teach Button
Temperature Effect (mm/°C)
0.2% of sensing distance/°C
Connection
Cable
QD Type/Cable Length
2 m
Number of Pins
5
Vibration
MIL-STD-202F req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock
IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage NPN Outputs
< 1.0 V at 10 mA ; < 1.5 V at 100 mA
Analog Current Output Rating
1 ? to [(Vcc-7 V)/0.02 A] ?
Max Discrete (Switched) Output (mA)
100
Discrete (Switched) Outputs
1 NPN
Output Protection
Protected against false pulse on power-up and continuous overload or short-circuit of outputs
IP Rating
IP67
NEMA Rating
NEMA 6P
Max Operating Temperature (°C)
70
Min Operating Temperature (°C)
-20
Max Op. Relative Humidity Non-Condensing (%)
100
Warm-up Time (minutes)
15
Minimum Response Time (ms)
96
Analog Linearity (mm)
+/- 0.5% of full-scale span
Barrel Diameter (mm)
30
Minimum Window Size (mm)
10
Remote Teach and Laser Control Input Impedence
55 k?
Discrete Output Hysteresis (mm)
2.5
Ultrasonic Frequency (kHz)
128
Max Off-state Leakage Current (μA)
10
Power/Current Consumption (exclusive of load)
90 mA
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Remote Teach
Yes
Feature: Clear Object Detection
Yes
Feature: Timing (Hold/Delay)
No
Feature: Chemical Resistant
No
Application: Ultrasonic
Yes
IO Link
No
RS-232
No
RS-422
No
RS-485
No
SSI
No
Wireless
No
1-wire Serial Interface
No
Profibus
No