Sensing Beam
-
Visible Red Laser
-
Max Measurement Range
-
>100 mm - <=500 mm
-
Power
-
DC
-
PC Configurable
-
No
-
Sensing Mode (General)
-
Proximity
-
Sensing Mode (Detailed)
-
Background/Foreground Suppression
-
Housing Style
-
Rectangular w/M18 Mount
-
Device Type
-
Sensor
-
Primary Housing Material
-
Stainless Steel
-
Laser Classification
-
Class 1
-
Input/Output
-
Discrete
-
Indicator
-
Display; LED(s)
-
Connection
-
Integral QD
-
Quick Disconnect Type
-
M12 (Euro)
-
Analog Resolution/Discrete Repeatability
-
25 mm to 50 mm: +/-0.5; 50 mm to 300 mm: +/- 1% of range
-
Max Sensing Distance (mm)
-
300
-
Minimum Sensing Distance (mm)
-
25
-
Power Supply
-
10-30 V dc
-
Delay at Power-up (ms)
-
750
-
Sensing Beam Wavelength (nm)
-
655
-
Adjustments
-
Push Button; Remote Teach
-
Temperature Effect (mm/°C)
-
+/- 0.05 mm/°C from 25 to 125 mm, +/- 0.35 mm/°C at 300 mm
-
Number of Pins
-
5
-
Vibration
-
MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
-
Mechanical Shock
-
MIL-STD-202G, Meth. 213B, Cond. I (100G 6x along X, Y & Z axes, 18 total shocks) w/ sensor operating
-
Output Saturation Voltage NPN Outputs
-
<1.0 V @ 100 mA
-
Output Saturation Voltage PNP Outputs
-
<1.5 V @ 100 mA
-
Max Discrete (Switched) Output (mA)
-
100
-
Discrete (Switched) Outputs
-
Bipolar (NPN & PNP)
-
Output Protection
-
Protected against continuous overload and short circuit
-
IP Rating
-
IP67; IP68; IP69
-
Storage Temperature (°C)
-
-25 to 75
-
Max Operating Temperature (°C)
-
50
-
Min Operating Temperature (°C)
-
-10
-
Max Op. Relative Humidity Non-Condensing (%)
-
95 at 55°C
-
Window Material
-
Acrylic
-
Warm-up Time (minutes)
-
10
-
Minimum Response Time (ms)
-
1.5
-
Spot Size (@ Reference Distance)
-
2.0 mm x 0.8 mm @ 300 mm
-
Barrel Diameter (mm)
-
18
-
Minimum Window Size (mm)
-
0.4
-
Discrete Output Hysteresis (mm)
-
Automatically adjusted
-
Laser Control
-
Yes
-
Alarm Output (mA)
-
100
-
Max Ambient Light (Lux)
-
5000
-
Max Off-state Leakage Current (μA)
-
5 @ 30 V dc
-
Power/Current Consumption (exclusive of load)
-
< 675 mW
-
Supply Protection Circuitry
-
Protected against reverse polarity and transient overvoltages
-
Feature: Remote Teach
-
Yes
-
Feature: Washdown Rated
-
Yes
-
Feature: Clear Object Detection
-
Yes
-
Feature: Timing (Hold/Delay)
-
Yes
-
Feature: Ecolab Certified
-
Yes
-
Feature: Chemical Resistant
-
Yes
-
Feature: Quick Disconnect
-
Yes
-
Common Ethernet Protocol
-
No
-
IO Link
-
No
-
PROFINET
-
No
-
RS-232
-
No
-
RS-422
-
No
-
RS-485
-
No
-
SSI
-
No
-
Wireless
-
No
-
1-wire Serial Interface
-
No
-
Profibus
-
No